Skip to content

Compare · inspect the limits, then line up the full specs

Inspect before you buy

Read the tool.
Know its limits.

Choose a meter, then a detail. The useful difference is often hiding behind the headline number.

Fluke 117 Electrician's True RMS Multimeter with Non-Contact Voltage
Manufacturer photograph · Fluke · original markings unchanged

Explore the actual tool

Fluke 117

Choose a reading lens

Marked measurement category

CAT III 600V

The category and its voltage belong together. Match both to the installation; the voltage range alone does not establish the category.

The buying trap. A capability or category marking does not approve the leads, setup or a live procedure.

Open the source rows
DC voltage
600 mV to 600 V; ±(0.5% + 2)
Safety rating
CAT III 600V (IEC 61010-1, pollution degree 2; IEC 61010-2-033)

Source record: 117

Manufacturer specifications recorded by thisMETER. These are not our own measurements. References belong to this product record; a field-by-field source mapping is not claimed.

DC voltage
600 mV to 600 V; ±(0.5% + 2)
Safety rating
CAT III 600V (IEC 61010-1, pollution degree 2; IEC 61010-2-033)

Record checked 2026-11-02.

Electrician’s True RMS meter with VoltAlert, automatic AC/DC selection and LoZ; includes leads and holster.

Fluke 117 standard package

Check price on Amazon

Fluke 117: Marked measurement category. CAT III 600V

One lens · actual tools

Compare the actual markings

Missing never becomes a pass.

Fluke
Fluke 117 Electrician's True RMS Multimeter with Non-Contact Voltage
Rating as recorded

Fluke 117

117

CAT III 600V

The category and its voltage belong together. Match both to the installation; the voltage range alone does not establish the category.

Check before buying. A capability or category marking does not approve the leads, setup or a live procedure.

Compare the source rows
DC voltage
600 mV to 600 V; ±(0.5% + 2)
Safety rating
CAT III 600V (IEC 61010-1, pollution degree 2; IEC 61010-2-033)

Source record: 117

Manufacturer specifications recorded by thisMETER. These are not our own measurements. References belong to this product record; a field-by-field source mapping is not claimed.

DC voltage
600 mV to 600 V; ±(0.5% + 2)
Safety rating
CAT III 600V (IEC 61010-1, pollution degree 2; IEC 61010-2-033)

Record checked 2026-11-02.

Brymen
Brymen BM235 Digital Multimeter
Rating as recorded

Brymen BM235

BM235

CAT III 600 V, CAT IV 300 V (per the linked BM230-series manual and the 2025 Brymen catalog; the product page alone prints 1000 V / CAT II 1000 V, which the manual's DC ranges ending 600.0 V do not support)

The category and its voltage belong together. Match both to the installation; the voltage range alone does not establish the category.

Check before buying. A capability or category marking does not approve the leads, setup or a live procedure.

Compare the source rows
DC voltage
60.00 mV, 600.0 mV, 6.000 V, 60.00 V, 600.0 V; ±(0.2% + 2 d) on the 60.00 mV / 600.0 mV / 6.000 V ranges, ±(0.5% + 3 d) on 60.00 V / 600.0 V
Safety rating
CAT III 600 V / CAT IV 300 V per the BM230-series manual and the 2025 Brymen catalog (the product page prints 1000 V / CAT II 1000 V, which the manual's ranges do not support)

Source record: BM235

Manufacturer specifications recorded by thisMETER. These are not our own measurements. References belong to this product record; a field-by-field source mapping is not claimed.

DC voltage
60.00 mV, 600.0 mV, 6.000 V, 60.00 V, 600.0 V; ±(0.2% + 2 d) on the 60.00 mV / 600.0 mV / 6.000 V ranges, ±(0.5% + 3 d) on 60.00 V / 600.0 V
Safety rating
CAT III 600 V / CAT IV 300 V per the BM230-series manual and the 2025 Brymen catalog (the product page prints 1000 V / CAT II 1000 V, which the manual's ranges do not support)

Record checked 2026-11-05.

Amprobe
Amprobe PM55A Pocket Multimeter with VolTect Non-Contact Voltage Detection
Needs maker confirmation

Amprobe PM55A

PM55A

Not recorded

The record has no confirmed CAT category and voltage pair. A marking in a photograph cannot fill that gap.

Check before buying. Confirm the exact model’s manual before considering it for mains measurements.

Compare the source rows

This field is not recorded. Check the exact model’s manufacturer documentation.

Source record: PM55A

Manufacturer specifications recorded by thisMETER. These are not our own measurements. References belong to this product record; a field-by-field source mapping is not claimed.

Voltage
AC and DC, 6.000 V, 60.00 V and 600.0 V ranges; DC accuracy ±(0.5% + 3 digits) at 6 V
AC/DC current
400.0 µA and 2000 µA ranges, ±(1.2% + 3 digits) DC at 2000 µA
Resistance
600.0 Ω to 6.000 MΩ, ±(1.0% + 4 digits) on the mid ranges
Capacitance
100.0 nF to 2000 µF, ±(3.5% + 6 digits)
Frequency
10.00 Hz to 30.00 kHz, ±(0.5% + 4 digits)
VolTect non-contact voltage
Built-in electric-field detection of AC voltage
AutoTect
Automatically selects AC V, DC V or resistance based on the test point
Display
6000 count, updates 5 per second nominal, large digits with unit icons
Overload protection
600 V DC and AC RMS; transient protection to 4 kV
Safety
CAT II 600 V, CAT III 300 V, Pollution Degree 2, Class 2; UL listed (cULus, EN61010-1)
Power
One 3 V CR2032 button cell; auto power off after 3 minutes idle
Size and weight
113 × 53 × 10.2 mm (about 3/8 in thick), approximately 78 g (under 3 oz)
What's included
PM55A and carrying case with battery installed, per the maker's page
Test leads
Red and black leads permanently attached

Record checked 2026-11-05.

Read the small print

A range is only part of the story.

A display count describes resolution, not accuracy. A current limit needs its fuse and duty conditions. A temperature range needs a suitably rated probe.

1 / 4 selected

Add a second product to see differences.

Maker specifications describe the recorded model and package. Missing measurements are labeled “Not recorded”.

Specification
REED R8090-NIST Sound Level Calibrator & NIST Certificate
REED R8090-NIST
Range94 and 114 dB calibration levels
Accuracy classIEC 60942 Class 2
Data loggingNot recorded
Best forNoise checks, Pros
Sources

Specifications checked November 5, 2026

View 2 sources
Retailer offerFind on Amazon
Choose another product · 156 in the catalog

Same-category models are suggested first. Choose All categories to mix categories.

Sound Level Meters

  • REED Instruments REED R1630 Light Meter, Bluetooth
    REED Instruments R1630REED Instruments
  • REED Instruments REED R8050 Dual Range Sound Level Meter
    REED Instruments R8050REED Instruments
  • REED Instruments REED R8050-KIT Sound Level Meter and Calibrator Kit
    REED Instruments R8050-KITREED Instruments
  • REED Instruments REED R8080 Data Logging Sound Level Meter with Bargraph
    REED Instruments R8080REED Instruments
  • REED Instruments REED R8080-KIT Data Logging Sound Level Meter and Calibrator Kit
    REED Instruments R8080-KITREED Instruments
  • REED Instruments REED R8090 Sound Level Calibrator
    REED Instruments R8090REED Instruments
  • REED R8080-KIT2 Data Logging Sound Meter with Tripod Kit
    REED R8080-KIT2REED
  • REED R8090-NIST Sound Level Calibrator & NIST Certificate