How to Measure Decibels

Make a Repeatable Home Noise Record

Measure home noise with repeatable settings, a copyable session sheet and a worked example. Choose a phone app, display meter or logger and read the results.

By thisMETER EditorialUpdated November 3, 20268 min read

On this page · Quick picks: choose the record you need

To measure decibels at home, fix the microphone position, select and record the weighting and response, check calibration and range, then measure the same operating condition for the same duration. Start with the NIOSH iOS app for occasional screening; our dedicated display pick is the REED R8050, while the R8080 adds timestamped logging. Write down the metric beside the number: a current reading, maximum and whole-session average answer different questions.

Quick picks: choose the record you need

Compare specifications and all conditions

NIOSH iOS app

Our pick for
Occasional screening and saved reports
Documented functions
A/C/Z weighting; LAeq, maximum and C-weighted peak
Important limit
Its Type 2 claim requires a calibrated external microphone

REED R8050

Our pick for
Reading a dedicated display yourself
Documented functions
30–130 dB; A/C; Fast/Slow; data hold and MAX
Important limit
No time-series logging or integrating LAeq documented

REED R8080

Our pick for
Keeping a timestamped history
Documented functions
30–130 dB; A/C; 64,000 stored datapoints; USB downloads
Important limit
Leq is described in PC software; standalone integrating LAeq is not established
Full comparison table

Swipe to compare. Row labels stay visible.

ChoiceOur pick forDocumented functionsImportant limit
NIOSH iOS appOccasional screening and saved reportsA/C/Z weighting; LAeq, maximum and C-weighted peakIts Type 2 claim requires a calibrated external microphone
REED R8050Reading a dedicated display yourself30–130 dB; A/C; Fast/Slow; data hold and MAXNo time-series logging or integrating LAeq documented
REED R8080Keeping a timestamped history30–130 dB; A/C; 64,000 stored datapoints; USB downloadsLeq is described in PC software; standalone integrating LAeq is not established
ChoiceOur pick forDocumented functionsImportant limit
NIOSH iOS appOccasional screening and saved reportsA/C/Z weighting; LAeq, maximum and C-weighted peakIts Type 2 claim requires a calibrated external microphone
REED R8050Reading a dedicated display yourself30–130 dB; A/C; Fast/Slow; data hold and MAXNo time-series logging or integrating LAeq documented
REED R8080Keeping a timestamped history30–130 dB; A/C; 64,000 stored datapoints; USB downloadsLeq is described in PC software; standalone integrating LAeq is not established

Sources: NIOSH specifications, R8050 manual, R8080 specifications and software guide. Recommendations reflect those functions.

Set up a comparison you can repeat

Write the question first: “Does changing the fan speed change the level at this chair?” Choose the condition to change deliberately; keep everything else as consistent as possible. Record the appliance setting, door/window positions, other running equipment and any interruptions. This is a practical home comparison plan, not a standardized appliance sound-power test.

REED's manuals specify keeping the meter away from your body, pointing its microphone toward the source and using a tripod for longer monitoring. They warn that blowing air can introduce errors; use the windscreen and avoid putting the microphone in an appliance's air stream. Mark the stand location, measure its height and distance from a named point on the source, and photograph the setup. Positioning instructions

Use this sequence for each session:

  1. Define the comparison

    Name the source setting, location and metric before starting.

  2. Fix the microphone

    Mark position, height and orientation; keep the setup clear of your body and blowing air.

  3. Check the instrument

    Follow its calibration procedure and choose a range without overload or under-range warnings.

  4. Record and repeat

    Keep duration and settings matched; preserve results and note interruptions.

Choose weighting, response and metric

Weighting: REED recommends A for general noise. Report it as dBA; label C-weighted results dBC. OSHA explains that A attenuates very low frequencies much more than C, so do not compare an A reading with a C reading as if only the source changed. Weighting explanation

Response: Fast has a 125 ms time constant; Slow has a 1 second time constant. Slow produces a short, time-weighted average that makes a fluctuating display easier to read, but does not establish an average over your whole session. OSHA response explanation The R8050 manual's wording “average sound level” for Slow describes that response setting; it documents no integrating LAeq function. REED settings

Metric: choose a current level for a spot check, MAX for the highest time-weighted reading, or LAeq for an equivalent continuous A-weighted level over the run. NIOSH lists LAeq, maximum and C-weighted peak separately; MAX is not a true peak measurement. Preserve the actual label and duration rather than relabelling every result “average dB.” NIOSH metric definitions

Check calibration and range before recording

NIOSH recommends calibration before and after measurements. Use the instrument's documented procedure and an appropriate reference; a quiet room or a video played through a speaker is not a known calibration reference. Record the calibrator/reference, its setting, the before/after indications and any adjustment. If you have no reference, write “not checked” instead of “calibrated.” Calibration guidance

The R8080 manual says UNDER means the selected range starts too high and OVER means its upper limit was exceeded. Change range and repeat the affected run. Both REED meters' published coverage starts at 30 dB: a result below that floor is outside their stated coverage, not a measurement of silence or an exact quieter level. Range instructions

Choose the duration before starting. For a cycling source, include the operating phase you intend to compare and document it. Keep talking, handling and unrelated interruptions out of the run, or mark them and repeat. Save the result before resetting; NIOSH provides Start, Pause, Reset and saved measurement reports in its help guide.

Copy this blank session record

Use a separate sheet for each condition. Leave unavailable metrics blank; do not manufacture them from a display reading.

Question and session ID

Fill in
___

Date, start/end time and duration

Fill in
___

Source, operating setting and phase

Fill in
___

Doors/windows, other equipment, source-off background if available

Fill in
___

Instrument; phone/app version and microphone if applicable

Fill in
___

Microphone location, height, distance reference, orientation; setup photo

Fill in
___

Weighting, Fast/Slow response and selected range

Fill in
___

Calibration reference; before/after indications; adjustment or not checked

Fill in
___

Result and exact metric; overload/under-range status

Fill in
___

Logging interval, export filename and software/calculation if used

Fill in
___

Interruptions, exclusions and reason to repeat

Fill in
___
Full comparison table

Swipe to compare. Row labels stay visible.

FieldFill in
Question and session ID___
Date, start/end time and duration___
Source, operating setting and phase___
Doors/windows, other equipment, source-off background if available___
Instrument; phone/app version and microphone if applicable___
Microphone location, height, distance reference, orientation; setup photo___
Weighting, Fast/Slow response and selected range___
Calibration reference; before/after indications; adjustment or not checked___
Result and exact metric; overload/under-range status___
Logging interval, export filename and software/calculation if used___
Interruptions, exclusions and reason to repeat___
FieldFill in
Question and session ID___
Date, start/end time and duration___
Source, operating setting and phase___
Doors/windows, other equipment, source-off background if available___
Instrument; phone/app version and microphone if applicable___
Microphone location, height, distance reference, orientation; setup photo___
Weighting, Fast/Slow response and selected range___
Calibration reference; before/after indications; adjustment or not checked___
Result and exact metric; overload/under-range status___
Logging interval, export filename and software/calculation if used___
Interruptions, exclusions and reason to repeat___

This worksheet combines REED's setup controls with NIOSH's report fields and calibration guidance; the extra context is our recommendation for making a comparison reviewable.

Worked example: compare matching records

Invented teaching example, not thisMETER readings or a prediction of fan performance. Our chosen plan is a steady fan at low versus high speed, unchanged room and stand, 60 seconds per run. The R8050 microphone is 1 m from the fan's front grille and 1 m above the floor, pointed toward it but outside the air stream. These distances and duration are example choices, not prescribed survey settings.

Source state throughout run

Record A
Fan low, oscillation off
Record B
Fan high, oscillation off

Room and microphone

Record A
Same marked tripod position; windows closed; no other appliance running
Record B
Unchanged

Instrument and settings

Record A
R8050; A weighting; Slow; low range 30–100 dB
Record B
Unchanged

Duration and metric

Record A
60 seconds; fresh MAX run
Record B
60 seconds; fresh MAX run

Illustrative result

Record A
MAX 50 dBA
Record B
MAX 60 dBA

Range warnings and interruptions

Record A
None
Record B
None

Calibration record

Record A
Not checked: no reference available
Record B
Not checked: no reference available
Full comparison table

Swipe to compare. Row labels stay visible.

Session fieldRecord ARecord B
Source state throughout runFan low, oscillation offFan high, oscillation off
Room and microphoneSame marked tripod position; windows closed; no other appliance runningUnchanged
Instrument and settingsR8050; A weighting; Slow; low range 30–100 dBUnchanged
Duration and metric60 seconds; fresh MAX run60 seconds; fresh MAX run
Illustrative resultMAX 50 dBAMAX 60 dBA
Range warnings and interruptionsNoneNone
Calibration recordNot checked: no reference availableNot checked: no reference available
Session fieldRecord ARecord B
Source state throughout runFan low, oscillation offFan high, oscillation off
Room and microphoneSame marked tripod position; windows closed; no other appliance runningUnchanged
Instrument and settingsR8050; A weighting; Slow; low range 30–100 dBUnchanged
Duration and metric60 seconds; fresh MAX run60 seconds; fresh MAX run
Illustrative resultMAX 50 dBAMAX 60 dBA
Range warnings and interruptionsNoneNone
Calibration recordNot checked: no reference availableNot checked: no reference available

The illustrative maxima differ by 10 dB. That comparison describes these matching MAX records; it does not supply LAeq, isolate the fan from background sound, or establish an accurately calibrated absolute level. Repeat the conditions, complete the calibration checks and investigate inconsistent repeats before relying on a small change. REED specifies ±1.4 dB accuracy, which is a manufacturer claim, not a complete uncertainty budget for this setup. R8050 specifications

  • Yes: Compare the same metric with matching weighting, response, placement and duration.
  • No: Do not substitute an under-range indication for a valid quieter reading.
  • No: Do not compare dBA with dBC or MAX with LAeq as equivalent results.
  • Partly: Stored samples describe a history; the averaging method still needs checking.

Decibels are logarithmic. OSHA specifically warns against calculating an average by adding the displayed levels and dividing by the sample count. Likewise, do not subtract a source-off dB reading from a source-on reading and call the difference the source's isolated level. Decibel arithmetic

Decibel level chart: examples, not household limits

NIDCD publishes these familiar-sound examples as average decibel ratings:

Normal conversation

Published example range
60–70 dBA

Movie theater

Published example range
74–104 dBA

Motorcycles and dirt bikes

Published example range
80–110 dBA
Full comparison table

Swipe to compare. Row labels stay visible.

SoundPublished example range
Normal conversation60–70 dBA
Movie theater74–104 dBA
Motorcycles and dirt bikes80–110 dBA
SoundPublished example range
Normal conversation60–70 dBA
Movie theater74–104 dBA
Motorcycles and dirt bikes80–110 dBA

Source: NIDCD sound examples. The ranges overlap; a label such as “movie theater” does not specify your microphone location or measurement duration. Use the chart to understand the scale, not to replace a reading at your chosen position.

Best screening starting point: NIOSH iOS app

The NIOSH app offers saved/shared reports and LAeq. Its published ±2 dBA accuracy comes from laboratory evaluation. The Type 2, IEC 61672 Part 3 claim requires a calibrated external microphone; the help guide describes evaluation of the complete phone/microphone system and continuing work on Parts 1 and 2.

The built-in-microphone setup and a calibrated external-microphone setup are different configurations. Record which you used. NIOSH currently cannot verify Android-app accuracy across that hardware range; do not transfer its results to a different app.

Best dedicated display: REED R8050

Choose the R8050 for manual spot checks and MAX records. REED specifies A/C weighting, Fast/Slow response and IEC 61672-1 Class 2; its documented functions do not include time-series logging or integrating LAeq.

Range conflict: the specification table gives high range 60–130 dB, while the operating instructions say 65–130 dB. Both give low range 30–100 dB. Confirm the transition with REED if it matters to your plan.

Package variant: the standard meter lists a windscreen, battery and case. REED's datasheet identifies R8050-KIT as the meter with an R8090 calibrator and R8888 hard case. That accessory bundle does not add logging. The manual describes requesting a calibration certificate separately, while the datasheet also lists R8050-NIST and R8050-KIT-NIST variants with NIST certification; check the documentation supplied with the exact package.

Best for stored history: REED R8080

The R8080 stores timestamped readings at intervals from 1 to 60 seconds. Set its clock and interval before recording. The interval is separate from Fast/Slow response: a stored point does not document everything between points.

REED describes CAL Leq in PC software; its software guide describes LEQ over a specified period and Excel export. The instrument manual does not establish onboard integrating LAeq. Preserve the original file and identify the software, interval and selected period behind any calculated result; request method details if a formal brief requires them.

The download support page lists Windows 11, while the software guide stops at Windows 10. Confirm installation compatibility before buying for exports; no macOS/Linux package is listed there.

Buying guide: when to change tools

Keep the display meter for a manual record; choose logging when you need timestamps and a history to inspect. For speaker/room tuning, REW's documentation describes a microphone/software setup that measures frequency and impulse responses. That is a different job from reporting an overall dB level. Use our home-theater SPL tools guide for that setup, or the sound level meter buying guide for broader tool selection.

How we choose

This is research from current official REED product pages, linked manuals and software documents, NIOSH guidance, NIDCD examples and REW documentation, checked November 2, 2026. Instrument specifications remain manufacturer claims; no physical product testing underlies these recommendations. The worksheet and hypothetical comparison are editorial teaching tools. See How we measure for our reporting policy.

Verdict

Start with a repeatable record: fixed placement, documented settings, matched duration and an accurately named metric. Use NIOSH on iOS for screening, the R8050 for dedicated display checks, or the R8080 for timestamped history. Keep microphone configuration, range warnings and calibration status attached to every comparison.

Frequently asked questions

Can I measure decibels with my phone?

For occasional screening, our starting point is the NIOSH Sound Level Meter app on iOS. NIOSH publishes accuracy within ±2 dBA from laboratory evaluation, and its Type 2 claim under IEC 61672 Part 3 requires a calibrated external microphone. Record the phone, app and microphone configuration. Those claims do not transfer to an arbitrary app, Android phone or uncalibrated microphone.

Should I use A or C weighting to measure noise?

For general home noise comparisons, start with A weighting and report dBA, unless your measurement procedure specifies otherwise. REED recommends A for general noise; OSHA explains that A attenuates low frequencies more than C. Keep C-weighted results separately labelled dBC. There is no universal offset that makes differently weighted readings interchangeable, so keep the weighting unchanged between comparison runs.

Does Slow response measure the average decibel level?

Slow produces a short, time-weighted average of sound pressure level using a one-second time constant, not an average across your entire recording. For a whole-session equivalent level, select an explicitly documented LAeq function and record its run time. The R8050 manual calls Slow an average sound level setting, but documents no integrating LAeq function. MAX retains a highest reading, while a logger stores samples; neither alone supplies the missing average.

How long should I measure noise?

Choose a duration that covers the event you want to compare, and use that duration again for the matching condition. Our worked example uses a deliberately chosen short interval for a steady fan; it is not a universal survey duration. If a source cycles, keep a record covering the cycle rather than comparing different operating phases. A brief home record cannot establish a full-shift noise exposure.