How to Measure Decibels
Make a Repeatable Home Noise Record
Measure home noise with repeatable settings, a copyable session sheet and a worked example. Choose a phone app, display meter or logger and read the results.
By thisMETER EditorialUpdated November 3, 20268 min read
On this page · Quick picks: choose the record you need
To measure decibels at home, fix the microphone position, select and record the weighting and response, check calibration and range, then measure the same operating condition for the same duration. Start with the NIOSH iOS app for occasional screening; our dedicated display pick is the REED R8050, while the R8080 adds timestamped logging. Write down the metric beside the number: a current reading, maximum and whole-session average answer different questions.
Quick picks: choose the record you need
Compare specifications and all conditions
NIOSH iOS app
- Our pick for
- Occasional screening and saved reports
- Documented functions
- A/C/Z weighting; LAeq, maximum and C-weighted peak
- Important limit
- Its Type 2 claim requires a calibrated external microphone
REED R8050
- Our pick for
- Reading a dedicated display yourself
- Documented functions
- 30–130 dB; A/C; Fast/Slow; data hold and MAX
- Important limit
- No time-series logging or integrating LAeq documented
REED R8080
- Our pick for
- Keeping a timestamped history
- Documented functions
- 30–130 dB; A/C; 64,000 stored datapoints; USB downloads
- Important limit
- Leq is described in PC software; standalone integrating LAeq is not established
Full comparison table
Swipe to compare. Row labels stay visible.
| Choice | Our pick for | Documented functions | Important limit |
|---|---|---|---|
| NIOSH iOS app | Occasional screening and saved reports | A/C/Z weighting; LAeq, maximum and C-weighted peak | Its Type 2 claim requires a calibrated external microphone |
| REED R8050 | Reading a dedicated display yourself | 30–130 dB; A/C; Fast/Slow; data hold and MAX | No time-series logging or integrating LAeq documented |
| REED R8080 | Keeping a timestamped history | 30–130 dB; A/C; 64,000 stored datapoints; USB downloads | Leq is described in PC software; standalone integrating LAeq is not established |
Scroll horizontally to see every column
| Choice | Our pick for | Documented functions | Important limit |
|---|---|---|---|
| NIOSH iOS app | Occasional screening and saved reports | A/C/Z weighting; LAeq, maximum and C-weighted peak | Its Type 2 claim requires a calibrated external microphone |
| REED R8050 | Reading a dedicated display yourself | 30–130 dB; A/C; Fast/Slow; data hold and MAX | No time-series logging or integrating LAeq documented |
| REED R8080 | Keeping a timestamped history | 30–130 dB; A/C; 64,000 stored datapoints; USB downloads | Leq is described in PC software; standalone integrating LAeq is not established |
Sources: NIOSH specifications, R8050 manual, R8080 specifications and software guide. Recommendations reflect those functions.
Set up a comparison you can repeat
Write the question first: “Does changing the fan speed change the level at this chair?” Choose the condition to change deliberately; keep everything else as consistent as possible. Record the appliance setting, door/window positions, other running equipment and any interruptions. This is a practical home comparison plan, not a standardized appliance sound-power test.
REED's manuals specify keeping the meter away from your body, pointing its microphone toward the source and using a tripod for longer monitoring. They warn that blowing air can introduce errors; use the windscreen and avoid putting the microphone in an appliance's air stream. Mark the stand location, measure its height and distance from a named point on the source, and photograph the setup. Positioning instructions
Use this sequence for each session:
Define the comparison
Name the source setting, location and metric before starting.
Fix the microphone
Mark position, height and orientation; keep the setup clear of your body and blowing air.
Check the instrument
Follow its calibration procedure and choose a range without overload or under-range warnings.
Record and repeat
Keep duration and settings matched; preserve results and note interruptions.
Choose weighting, response and metric
Weighting: REED recommends A for general noise. Report it as dBA; label C-weighted results dBC. OSHA explains that A attenuates very low frequencies much more than C, so do not compare an A reading with a C reading as if only the source changed. Weighting explanation
Response: Fast has a 125 ms time constant; Slow has a 1 second time constant. Slow produces a short, time-weighted average that makes a fluctuating display easier to read, but does not establish an average over your whole session. OSHA response explanation The R8050 manual's wording “average sound level” for Slow describes that response setting; it documents no integrating LAeq function. REED settings
Metric: choose a current level for a spot check, MAX for the highest time-weighted reading, or LAeq for an equivalent continuous A-weighted level over the run. NIOSH lists LAeq, maximum and C-weighted peak separately; MAX is not a true peak measurement. Preserve the actual label and duration rather than relabelling every result “average dB.” NIOSH metric definitions
Check calibration and range before recording
NIOSH recommends calibration before and after measurements. Use the instrument's documented procedure and an appropriate reference; a quiet room or a video played through a speaker is not a known calibration reference. Record the calibrator/reference, its setting, the before/after indications and any adjustment. If you have no reference, write “not checked” instead of “calibrated.” Calibration guidance
The R8080 manual says UNDER means the selected range starts too high and OVER means its upper limit was exceeded. Change range and repeat the affected run. Both REED meters' published coverage starts at 30 dB: a result below that floor is outside their stated coverage, not a measurement of silence or an exact quieter level. Range instructions
Choose the duration before starting. For a cycling source, include the operating phase you intend to compare and document it. Keep talking, handling and unrelated interruptions out of the run, or mark them and repeat. Save the result before resetting; NIOSH provides Start, Pause, Reset and saved measurement reports in its help guide.
Copy this blank session record
Use a separate sheet for each condition. Leave unavailable metrics blank; do not manufacture them from a display reading.
Question and session ID
- Fill in
- ___
Date, start/end time and duration
- Fill in
- ___
Source, operating setting and phase
- Fill in
- ___
Doors/windows, other equipment, source-off background if available
- Fill in
- ___
Instrument; phone/app version and microphone if applicable
- Fill in
- ___
Microphone location, height, distance reference, orientation; setup photo
- Fill in
- ___
Weighting, Fast/Slow response and selected range
- Fill in
- ___
Calibration reference; before/after indications; adjustment or not checked
- Fill in
- ___
Result and exact metric; overload/under-range status
- Fill in
- ___
Logging interval, export filename and software/calculation if used
- Fill in
- ___
Interruptions, exclusions and reason to repeat
- Fill in
- ___
Full comparison table
Swipe to compare. Row labels stay visible.
| Field | Fill in |
|---|---|
| Question and session ID | ___ |
| Date, start/end time and duration | ___ |
| Source, operating setting and phase | ___ |
| Doors/windows, other equipment, source-off background if available | ___ |
| Instrument; phone/app version and microphone if applicable | ___ |
| Microphone location, height, distance reference, orientation; setup photo | ___ |
| Weighting, Fast/Slow response and selected range | ___ |
| Calibration reference; before/after indications; adjustment or not checked | ___ |
| Result and exact metric; overload/under-range status | ___ |
| Logging interval, export filename and software/calculation if used | ___ |
| Interruptions, exclusions and reason to repeat | ___ |
Scroll horizontally to see every column
| Field | Fill in |
|---|---|
| Question and session ID | ___ |
| Date, start/end time and duration | ___ |
| Source, operating setting and phase | ___ |
| Doors/windows, other equipment, source-off background if available | ___ |
| Instrument; phone/app version and microphone if applicable | ___ |
| Microphone location, height, distance reference, orientation; setup photo | ___ |
| Weighting, Fast/Slow response and selected range | ___ |
| Calibration reference; before/after indications; adjustment or not checked | ___ |
| Result and exact metric; overload/under-range status | ___ |
| Logging interval, export filename and software/calculation if used | ___ |
| Interruptions, exclusions and reason to repeat | ___ |
This worksheet combines REED's setup controls with NIOSH's report fields and calibration guidance; the extra context is our recommendation for making a comparison reviewable.
Worked example: compare matching records
Invented teaching example, not thisMETER readings or a prediction of fan performance. Our chosen plan is a steady fan at low versus high speed, unchanged room and stand, 60 seconds per run. The R8050 microphone is 1 m from the fan's front grille and 1 m above the floor, pointed toward it but outside the air stream. These distances and duration are example choices, not prescribed survey settings.
Source state throughout run
- Record A
- Fan low, oscillation off
- Record B
- Fan high, oscillation off
Room and microphone
- Record A
- Same marked tripod position; windows closed; no other appliance running
- Record B
- Unchanged
Instrument and settings
- Record A
- R8050; A weighting; Slow; low range 30–100 dB
- Record B
- Unchanged
Duration and metric
- Record A
- 60 seconds; fresh MAX run
- Record B
- 60 seconds; fresh MAX run
Illustrative result
- Record A
- MAX 50 dBA
- Record B
- MAX 60 dBA
Range warnings and interruptions
- Record A
- None
- Record B
- None
Calibration record
- Record A
- Not checked: no reference available
- Record B
- Not checked: no reference available
Full comparison table
Swipe to compare. Row labels stay visible.
| Session field | Record A | Record B |
|---|---|---|
| Source state throughout run | Fan low, oscillation off | Fan high, oscillation off |
| Room and microphone | Same marked tripod position; windows closed; no other appliance running | Unchanged |
| Instrument and settings | R8050; A weighting; Slow; low range 30–100 dB | Unchanged |
| Duration and metric | 60 seconds; fresh MAX run | 60 seconds; fresh MAX run |
| Illustrative result | MAX 50 dBA | MAX 60 dBA |
| Range warnings and interruptions | None | None |
| Calibration record | Not checked: no reference available | Not checked: no reference available |
Scroll horizontally to see every column
| Session field | Record A | Record B |
|---|---|---|
| Source state throughout run | Fan low, oscillation off | Fan high, oscillation off |
| Room and microphone | Same marked tripod position; windows closed; no other appliance running | Unchanged |
| Instrument and settings | R8050; A weighting; Slow; low range 30–100 dB | Unchanged |
| Duration and metric | 60 seconds; fresh MAX run | 60 seconds; fresh MAX run |
| Illustrative result | MAX 50 dBA | MAX 60 dBA |
| Range warnings and interruptions | None | None |
| Calibration record | Not checked: no reference available | Not checked: no reference available |
The illustrative maxima differ by 10 dB. That comparison describes these matching MAX records; it does not supply LAeq, isolate the fan from background sound, or establish an accurately calibrated absolute level. Repeat the conditions, complete the calibration checks and investigate inconsistent repeats before relying on a small change. REED specifies ±1.4 dB accuracy, which is a manufacturer claim, not a complete uncertainty budget for this setup. R8050 specifications
- Yes: Compare the same metric with matching weighting, response, placement and duration.
- No: Do not substitute an under-range indication for a valid quieter reading.
- No: Do not compare dBA with dBC or MAX with LAeq as equivalent results.
- Partly: Stored samples describe a history; the averaging method still needs checking.
Decibels are logarithmic. OSHA specifically warns against calculating an average by adding the displayed levels and dividing by the sample count. Likewise, do not subtract a source-off dB reading from a source-on reading and call the difference the source's isolated level. Decibel arithmetic
Decibel level chart: examples, not household limits
NIDCD publishes these familiar-sound examples as average decibel ratings:
Normal conversation
- Published example range
- 60–70 dBA
Movie theater
- Published example range
- 74–104 dBA
Motorcycles and dirt bikes
- Published example range
- 80–110 dBA
Full comparison table
Swipe to compare. Row labels stay visible.
| Sound | Published example range |
|---|---|
| Normal conversation | 60–70 dBA |
| Movie theater | 74–104 dBA |
| Motorcycles and dirt bikes | 80–110 dBA |
Scroll horizontally to see every column
| Sound | Published example range |
|---|---|
| Normal conversation | 60–70 dBA |
| Movie theater | 74–104 dBA |
| Motorcycles and dirt bikes | 80–110 dBA |
Source: NIDCD sound examples. The ranges overlap; a label such as “movie theater” does not specify your microphone location or measurement duration. Use the chart to understand the scale, not to replace a reading at your chosen position.
Best screening starting point: NIOSH iOS app
The NIOSH app offers saved/shared reports and LAeq. Its published ±2 dBA accuracy comes from laboratory evaluation. The Type 2, IEC 61672 Part 3 claim requires a calibrated external microphone; the help guide describes evaluation of the complete phone/microphone system and continuing work on Parts 1 and 2.
The built-in-microphone setup and a calibrated external-microphone setup are different configurations. Record which you used. NIOSH currently cannot verify Android-app accuracy across that hardware range; do not transfer its results to a different app.
Best dedicated display: REED R8050
Choose the R8050 for manual spot checks and MAX records. REED specifies A/C weighting, Fast/Slow response and IEC 61672-1 Class 2; its documented functions do not include time-series logging or integrating LAeq.
Range conflict: the specification table gives high range 60–130 dB, while the operating instructions say 65–130 dB. Both give low range 30–100 dB. Confirm the transition with REED if it matters to your plan.
Package variant: the standard meter lists a windscreen, battery and case. REED's datasheet identifies R8050-KIT as the meter with an R8090 calibrator and R8888 hard case. That accessory bundle does not add logging. The manual describes requesting a calibration certificate separately, while the datasheet also lists R8050-NIST and R8050-KIT-NIST variants with NIST certification; check the documentation supplied with the exact package.
Best for stored history: REED R8080
The R8080 stores timestamped readings at intervals from 1 to 60 seconds. Set its clock and interval before recording. The interval is separate from Fast/Slow response: a stored point does not document everything between points.
REED describes CAL Leq in PC software; its software guide describes LEQ over a specified period and Excel export. The instrument manual does not establish onboard integrating LAeq. Preserve the original file and identify the software, interval and selected period behind any calculated result; request method details if a formal brief requires them.
The download support page lists Windows 11, while the software guide stops at Windows 10. Confirm installation compatibility before buying for exports; no macOS/Linux package is listed there.
Buying guide: when to change tools
Keep the display meter for a manual record; choose logging when you need timestamps and a history to inspect. For speaker/room tuning, REW's documentation describes a microphone/software setup that measures frequency and impulse responses. That is a different job from reporting an overall dB level. Use our home-theater SPL tools guide for that setup, or the sound level meter buying guide for broader tool selection.
How we choose
This is research from current official REED product pages, linked manuals and software documents, NIOSH guidance, NIDCD examples and REW documentation, checked November 2, 2026. Instrument specifications remain manufacturer claims; no physical product testing underlies these recommendations. The worksheet and hypothetical comparison are editorial teaching tools. See How we measure for our reporting policy.
Verdict
Start with a repeatable record: fixed placement, documented settings, matched duration and an accurately named metric. Use NIOSH on iOS for screening, the R8050 for dedicated display checks, or the R8080 for timestamped history. Keep microphone configuration, range warnings and calibration status attached to every comparison.
Frequently asked questions
Can I measure decibels with my phone?
For occasional screening, our starting point is the NIOSH Sound Level Meter app on iOS. NIOSH publishes accuracy within ±2 dBA from laboratory evaluation, and its Type 2 claim under IEC 61672 Part 3 requires a calibrated external microphone. Record the phone, app and microphone configuration. Those claims do not transfer to an arbitrary app, Android phone or uncalibrated microphone.
Should I use A or C weighting to measure noise?
For general home noise comparisons, start with A weighting and report dBA, unless your measurement procedure specifies otherwise. REED recommends A for general noise; OSHA explains that A attenuates low frequencies more than C. Keep C-weighted results separately labelled dBC. There is no universal offset that makes differently weighted readings interchangeable, so keep the weighting unchanged between comparison runs.
Does Slow response measure the average decibel level?
Slow produces a short, time-weighted average of sound pressure level using a one-second time constant, not an average across your entire recording. For a whole-session equivalent level, select an explicitly documented LAeq function and record its run time. The R8050 manual calls Slow an average sound level setting, but documents no integrating LAeq function. MAX retains a highest reading, while a logger stores samples; neither alone supplies the missing average.
How long should I measure noise?
Choose a duration that covers the event you want to compare, and use that duration again for the matching condition. Our worked example uses a deliberately chosen short interval for a steady fan; it is not a universal survey duration. If a source cycles, keep a record covering the cycle rather than comparing different operating phases. A brief home record cannot establish a full-shift noise exposure.
Related guides
Best picks · Sound Level Meters
Best SPL Meters for Home Theater: Meter or Calibrated Mic?
Choose an SPL meter or calibrated mic for home theater: compare REED R8050, UMIK-1 and iMM-6C setups, calibration files, required apps and useful data exports.
Comparison · Sound Level Meters
REED R8050 vs R8080: Spot Readings or Saved Sound Records?
Choose the REED R8050 for spot readings or R8080 for saved sound data. Compare ranges, Windows exports, calibration kits and the exact accessories you need.
Best picks · Sound Level Meters
Best Sound Level Meters: When a Phone App Is Enough
Choose a sound level meter for spot checks or logging, see when the NIOSH iOS app is enough, and understand weighting, calibration and Class 1 versus Class 2.