Marked measurement category

Not recorded

The record has no confirmed CAT category and voltage pair. A marking in a photograph cannot fill that gap.

The buying trap. Confirm the exact model’s manual before considering it for mains measurements.

Open the source rows
DC voltage
Max 1000 V; ±(0.05% + 1); 10 μV maximum resolution

Source record: 87V

Manufacturer specifications recorded by thisMETER. These are not our own measurements. References belong to this product record; a field-by-field source mapping is not claimed.

DC voltage
Max 1000 V; ±(0.05% + 1); 10 μV maximum resolution

Record checked 2026-11-05.

Fluke 87V. Not recorded

We may earn a commission. How we earn.

The industrial true-rms multimeter itself.

Fluke 87V

Check price on Amazon

Specifications checked November 5, 2026. Full product details

Fluke 87V Industrial Multimeter

Fluke's true-rms industrial digital multimeter, with CAT III 1000 V / CAT IV 600 V inputs, a low-pass filter for VFD work, and 0.05% DC voltage accuracy.

Which version should you buy?

Selected package: Fluke 87V.

Selected package

  • Fluke 87V

    This page

    Model: 87V

    What differs
    The industrial true-rms multimeter itself.
    Best for
    Motor drives, automation and high-accuracy DC work.

Related models and generations

These are different products. Check their specifications separately.

  • Fluke 87V MAX Model: 87V MAX

    IP54 ruggedized version with removable holster and much longer runtime.

    Harsh outdoor industrial environments.

Purchase links appear where the exact offer is verified. Confirm the named model, quantity and accessories before ordering.

Watch out

  • An 88V is automotive (duty cycle, RPM), not the 87V's accuracy.
  • Listings with the case and i400 are Truerms bundles, not the 87V alone.

Why people pick it

  • 0.05% DC voltage accuracy and 19,999-count high-resolution mode, per the spec sheet
  • Low-pass filter for accurate measurements on variable-frequency drives, plus Peak Capture for 250 μs intermittents
  • CAT III 1000 V / CAT IV 600 V inputs rated for over 8000 V spikes, with an audible wrong-jack warning
  • Analog bar graph and Touch Hold make fast-changing or unstable signals usable; lifetime warranty

Know before you buy

  • 10 A current inputs (20 A only for 30 seconds) - current-heavy work needs a clamp accessory
  • No built-in wireless logging (the 87V is not a Fluke Connect instrument)
  • Bench-style size and weight for a handheld, and a premium price tier

Full specifications

DC voltageMax 1000 V; ±(0.05% + 1); 10 μV maximum resolution
AC voltageMax 1000 V; ±(0.7% + 2) true-rms; 20 kHz bandwidth with low-pass filter (3 dB @ 1 kHz); 0.1 mV maximum resolution
DC currentMax 10 A (20 A for 30 seconds max); ±(0.2% + 2); 0.01 μA maximum resolution
AC currentMax 10 A (20 A for 30 seconds max); ±(1.0% + 2) true-rms; 0.1 μA maximum resolution
ResistanceMax 50 MΩ; ±(0.2% + 1); 0.1 Ω maximum resolution
CapacitanceMax 9,999 μF; ±(1% + 2)
FrequencyMax 200 kHz; ±(0.005% + 1)
Duty cycleMax 99.9%; ±(0.2% per kHz + 0.1%)
Temperature-200.0 °C to 1090 °C (-328 to 1994 °F) with the 80 BK probe: -40 °C to 260 °C
Conductance60.00 nS; ±(1.0% + 10)
Diode test3 V range, 1 mV resolution, ±(2% + 1)
Display6000 counts (19,999 counts in high-resolution mode), 4/sec; 32-segment analog bar graph, 40/sec; two-level backlight
Peak CaptureCaptures intermittents as fast as 250 μs
SafetyEN 61010-1 3rd edition, 1000 V CAT III / 600 V CAT IV; designed to withstand spikes over 8000 V; audible input alert for wrong jacks; 1 m drop per IEC 61010-1
Operating temperature-20 °C to +55 °C; operating altitude 2000 m
Battery lifeAbout 400 hours alkaline without backlight
Size and weight201 × 98 × 52 mm with holster; 355 g (624 g with holster)
WarrantyLifetime warranty; designed and built in the U.S.
What's in the box87V multimeter, TL75 test leads, AC175 alligator clips, holster, 9 V battery installed, 80BK temperature probe

From manufacturer documentation, checked November 5, 2026. Spotted an error? Tell us.

Alternatives to consider

FLIR DM66 TRMS Digital Multimeter with VFD Mode

FLIR DM66

Max voltage
600 V
Safety rating
CAT IV 300V, CAT III 600V
Specifications & conditions
Max current
10 A

A True RMS digital multimeter for field service and electronics work, with a low-impedance mode, VFD-filtered voltage readings, capacitance, frequency and a Type K thermocouple input, rated CAT IV 300 V / CAT III 600 V.

Check package and model options

  • Electronics
  • Pros
  • Automotive
FLIR DM93-2 Industrial Digital Multimeter with Meterlink

FLIR DM93-2

Max voltage
1,000 V
Display counts
40,000 counts
Specifications & conditions
Safety rating
CAT IV-600 V, CAT III-1000 V
Max current
10 A

A 40,000-count True RMS industrial digital multimeter with VFD low-pass filtering, a LoZ ghost-voltage mode, CAT IV-600 V / CAT III-1000 V inputs and Bluetooth streaming to the FLIR METERLiNK app.

Check package and model options

  • Pros
  • Electronics
  • Automotive
Fluke 287 FlukeView Forms Combo Kit (287/FVF)

Fluke 287/FVF

Max voltage
1,000 V
Display counts
50,000 counts
Specifications & conditions
Safety rating
CAT III 1000V, CAT II 1000V (leads)

A 50,000-count true-RMS logging multimeter bundled with FlukeView Forms software, a thermocouple probe, modular test leads and a magnetic hanging strap, for long-term troubleshooting and reporting.

Check package and model options

  • Electronics
  • Pros