A palm-size 6,000-count multimeter rated CAT III 600V that measures AC and DC voltage and current to 600 V and 10 A, plus resistance, capacitance, frequency and duty cycle; it is not True RMS.

Fluke 107 pocket digital multimeter, front view
1 / 1 · hero · hover to zoom

Photo: Fluke

Key facts

DC voltage
6 V, 60 V and 600 V ranges; ±(0.5% + 3)
AC voltage
6 V, 60 V and 600 V ranges, 40 to 500 Hz; ±(1.0% + 3); not True RMS
AC millivolts
600 mV; ±(3.0% + 3)
AC and DC current
4 A and 10 A ranges; ±(1.5% + 3); AC 40 to 200 Hz
Resistance
400 Ω to 40 MΩ; ±(0.5% + 2) from 4 kΩ to 4 MΩ, ±(1.5% + 3) on 40 MΩ
Capacitance
50 nF to 1,000 µF; ±(2% + 5) up to 500 nF, ±(5% + 5) above
Frequency
10 Hz to 100 kHz; ±(0.1% + 3)

Which version should you buy?

This page covers: Fluke 107 with TL75 leads and SmartStrap.

  • Fluke 107 standard package

    This page

    Model: 107 (part 4367953)

    What differs
    Pocket meter with TL75 leads and SmartStrap; adds diode, frequency and duty-cycle tests over the 106.
    Best for
    Everyday electrical checks where True RMS accuracy is unnecessary.
  • Fluke 106 pocket meter

    Model: 106

    What differs
    Simpler sibling that retains capacitance measurement; diode, frequency and duty-cycle tests are 107-only functions.
    Best for
    Basic voltage, current, resistance and capacitance checks.
  • Fluke 107 with BK120 breaker finder

    Model: BK120/107 Kit (part 5587530)

    What differs
    Adds a BK120 breaker-finder receiver and transmitter to the 107 meter package.
    Best for
    Buyers needing to identify circuit breakers as well as take meter readings.

Watch out

  • The standard 107 package already includes TL75 leads and SmartStrap; the BK120 kit adds a separate breaker finder.
  • Both 106 and 107 measure capacitance; diode, frequency and duty cycle distinguish the 107.
  • The 107 is not a True RMS meter.
  • Duplicate or newer 107 listing titles do not establish a new meter generation.

Why people pick it

  • Pocket-size Fluke rated CAT III 600V
  • 6,000-count display with backlight and data hold
  • Adds capacitance, frequency and duty cycle to the basics
  • Magnetic SmartStrap hangs it from any steel surface

Know before you buy

  • Not True RMS: Fluke positions it for jobs where True RMS accuracy isn't needed
  • No microamp or milliamp ranges; current starts at the 4 A range
  • Rated for a 1 m drop (Klein rates its MM420 for 2 m)
  • Fluke lists no non-contact voltage detection or LoZ mode

Full specifications

DC voltage6 V, 60 V and 600 V ranges; ±(0.5% + 3)
AC voltage6 V, 60 V and 600 V ranges, 40 to 500 Hz; ±(1.0% + 3); not True RMS
AC millivolts600 mV; ±(3.0% + 3)
AC and DC current4 A and 10 A ranges; ±(1.5% + 3); AC 40 to 200 Hz
Resistance400 Ω to 40 MΩ; ±(0.5% + 2) from 4 kΩ to 4 MΩ, ±(1.5% + 3) on 40 MΩ
Capacitance50 nF to 1,000 µF; ±(2% + 5) up to 500 nF, ±(5% + 5) above
Frequency10 Hz to 100 kHz; ±(0.1% + 3)
Duty cycle1% to 99%
Diode and continuityDiode test (2 V range) and continuity
Display6,000 counts, 3 updates per second; backlight; data hold
Safety ratingCAT III 600V (IEC 61010-1, pollution degree 2)
Current fuse11 A, 1000 V fast fuse
Ingress protectionIP40
Drop rating1 m
Battery2 × AAA; at least 200 hours
Accuracy periodOne year after calibration, at 18 to 28°C
Size142 × 69 × 28 mm
Weight200 g
Warranty2 years (manual)
In the boxMeter, TL75 Hard Point test leads, 2 × AAA batteries (installed), SmartStrap magnetic lanyard

From manufacturer documentation, checked November 2, 2026. Spotted an error? Tell us.