Skip to content

Explainer

Bosch GDM600-15: Which US Package and Battery Should You Buy?

Choose the Bosch GDM600-15 US multimeter package. Compare included leads and AA power, the optional rechargeable battery, missing functions and alternatives.

By thisMETER EditorialUpdated November 3, 20267 min read2 picks

On this page · Quick picks: choose the complete package

Choose the US Bosch GDM600-15, order 0601077310 if you want a True RMS, CAT III 600 V multimeter for voltage, continuity and general electrical troubleshooting. Start with its included AA batteries, MS90 silicone leads and pouch; add GBA37V10 only if you prefer rechargeable power. Choose Klein MM420 for dedicated microamp ranges and temperature, or Fluke 117 for ghost-voltage rejection and built-in non-contact detection.

Quick picks: choose the complete package

Compare specifications and all conditions

A Bosch multimeter for general electrical checks

Our pick
US GDM600-15 standard package
What to buy or check
Start with the included leads, pouch and AA power; no rechargeable pack is required

Rechargeable power for that meter

Our pick
GBA37V10, optional
What to buy or check
Battery package includes a USB-A-to-USB-C cable; arrange the specified USB supply and charge outside the meter

Small-current work, temperature or diode testing

Our pick
Klein MM420
What to buy or check
Includes leads, thermocouple and AAA batteries; check probe limits

Ghost-voltage troubleshooting

Our pick
Fluke 117
What to buy or check
LoZ, AutoVolt and VoltAlert; standard package includes silicone leads and holster
Full comparison table

Swipe to compare. Row labels stay visible.

Your priorityOur pickWhat to buy or check
A Bosch multimeter for general electrical checksUS GDM600-15 standard packageStart with the included leads, pouch and AA power; no rechargeable pack is required
Rechargeable power for that meterGBA37V10, optionalBattery package includes a USB-A-to-USB-C cable; arrange the specified USB supply and charge outside the meter
Small-current work, temperature or diode testingKlein MM420Includes leads, thermocouple and AAA batteries; check probe limits
Ghost-voltage troubleshootingFluke 117LoZ, AutoVolt and VoltAlert; standard package includes silicone leads and holster
Your priorityOur pickWhat to buy or check
A Bosch multimeter for general electrical checksUS GDM600-15 standard packageStart with the included leads, pouch and AA power; no rechargeable pack is required
Rechargeable power for that meterGBA37V10, optionalBattery package includes a USB-A-to-USB-C cable; arrange the specified USB supply and charge outside the meter
Small-current work, temperature or diode testingKlein MM420Includes leads, thermocouple and AAA batteries; check probe limits
Ghost-voltage troubleshootingFluke 117LoZ, AutoVolt and VoltAlert; standard package includes silicone leads and holster

The specifications below come from the linked maker pages and manuals. For a wider shortlist, see our best multimeters; this page focuses on the Bosch purchase and the functions that might redirect it.

Best Bosch starting package: US GDM600-15

Bosch's US product page documents a package containing the meter, tool pouch, MS90 test leads and two AA batteries. It lists flexible silicone leads, an integrated kickstand, a high-contrast LCD and rubber-reinforced housing rated for 6 ft drops. A magnetic hanger is sold separately: buy the standard package first unless hanging the meter is part of your routine.

The linked US GDM600-15 manual specifies 600 V AC/DC, 10 A AC/DC, 40 MΩ resistance and 1,000 µF capacitance. Frequency extends to 50 kHz from AC voltage or 2 kHz from AC current, subject to the manual's input conditions. It also provides continuity, automatic/manual ranging and Min/Max/Average readings.

  • 600 V AC/DCBosch's voltage ceiling; meter rated CAT III 600 V
  • 10 A AC/DCMaximum current; time limit applies
  • 1,000 µFMaximum capacitance in the US manual

The current ceiling is not continuous: Bosch limits a maximum-current measurement to 10 seconds, followed by 15 minutes between maximum-current measurements. Its smallest current range is 6.000 A, resolving 0.001 A (1 mA). Those details matter more than the maximum when choosing a meter for small-current work.

For DC voltage, Bosch specifies ±(0.5% of reading + 2 counts). The accuracy table's reference conditions are 18–28°C and ≤75% relative humidity, with an additional temperature error outside that band. This is a manufacturer specification, not a result from thisMETER.

Check the US GDM600-15 package with Bosch

US GDM600-15 versus regional GDM 600-15 listings

The space in the name is a poor package identifier. Bosch's US URL identifies 0601077310, while its spare-parts section and US manual identify the tool as 3601K77310. Keep those identifiers distinct when ordering the meter versus requesting service parts.

Bosch's UK GDM 600-15 page documents different regional packages:

  • 0 601 077 300: pouch, MS 90 leads and two AA batteries.
  • 0 601 077 301: those contents plus the MH 1 magnetic hanger.

That UK page identifies the leads as 1 600 A03 8D2 and hanger as 1 600 A03 8CY. The US manual instead lists 1600A03TC8 test leads and 1600A03TC9 magnetic hanger. Do not assume matching accessory names establish interchangeable regional order numbers; use the US manual and Bosch's confirmation for replacements.

A maker wording mismatch: the US retail page explicitly includes AA batteries, but the manual's AA-power paragraph calls them sold separately. We use the US product page for the advertised package contents and the manual for operating limits. Have the seller confirm the contents of the actual box.

Optional rechargeable power: Bosch GBA37V10

Buy this accessory only if recharging fits your routine. The meter works on two 1.5 V LR6 AA alkaline batteries, or the manual's named BA 3.7V 1.0Ah A (GBA37V10) lithium-ion pack. Its compatibility instruction permits only the packs listed in its technical data; an existing Bosch power-tool battery collection does not establish a compatible supply.

Bosch's GBA37V10 page describes it as formerly GLM-BAT and includes one battery and a USB-A-to-USB-C cable. A wall adapter is not in that contents list. The meter manual specifies a 5 V DC, 500 mA USB supply and recommends cables 2610067499 or 6082942Z0Z; check the supplied cable against those requirements.

Remove the pack to charge it. The USB-C socket is on the battery, and the GDM600-15 manual requires taking the pack out of the meter for charging. The battery product page's permission to charge while installed specifically describes a laser, so it is not a pass-through-power claim for this meter. Keep the AA cover inlay for switching back to alkaline power; the manual requires that inlay for AA operation.

The meter manual permits charging at 10–35°C. The older battery manual linked by Bosch gives a wider above 0°C and below 45°C window; use the narrower meter-specific window for this combination. Bosch's battery page also shows service part 1608M00C44, whereas the meter manual lists pack article 1607A350N9. Confirm the named compatible pack with Bosch if an order is identified only by one of these numbers.

Check GBA37V10 contents with Bosch

Compare Bosch with the Klein and Fluke routes

All three makers specify True RMS and CAT III 600 V for these meters. The useful differences are the available functions, small-current detail and included accessories.

AC/DC voltage and current ceilings

Bosch GDM600-15
600 V / 10 A
Klein MM420
600 V / 10 A
Fluke 117
600 V / 10 A

Smallest DC current range; resolution

Bosch GDM600-15
6.000 A; 1 mA
Klein MM420
400 µA; 0.1 µA
Fluke 117
6.000 A; 1 mA

Temperature, diode test, duty cycle

Bosch GDM600-15
None listed in the US manual
Klein MM420
All listed
Fluke 117
Diode test; no temperature or duty cycle listed

LoZ voltage / built-in non-contact detection

Bosch GDM600-15
Neither listed
Klein MM420
Neither listed
Fluke 117
Both; also AutoVolt

Power

Bosch GDM600-15
Two AA or optional GBA37V10
Klein MM420
Two AAA
Fluke 117
9 V alkaline

Standard accessories

Bosch GDM600-15
MS90 leads, pouch, AA batteries
Klein MM420
Capped leads, thermocouple, AAA batteries
Fluke 117
Silicone leads and holster
Full comparison table

Swipe to compare. Row labels stay visible.

Buying requirementBosch GDM600-15Klein MM420Fluke 117
AC/DC voltage and current ceilings600 V / 10 A600 V / 10 A600 V / 10 A
Smallest DC current range; resolution6.000 A; 1 mA400 µA; 0.1 µA6.000 A; 1 mA
Temperature, diode test, duty cycleNone listed in the US manualAll listedDiode test; no temperature or duty cycle listed
LoZ voltage / built-in non-contact detectionNeither listedNeither listedBoth; also AutoVolt
PowerTwo AA or optional GBA37V10Two AAA9 V alkaline
Standard accessoriesMS90 leads, pouch, AA batteriesCapped leads, thermocouple, AAA batteriesSilicone leads and holster
Buying requirementBosch GDM600-15Klein MM420Fluke 117
AC/DC voltage and current ceilings600 V / 10 A600 V / 10 A600 V / 10 A
Smallest DC current range; resolution6.000 A; 1 mA400 µA; 0.1 µA6.000 A; 1 mA
Temperature, diode test, duty cycleNone listed in the US manualAll listedDiode test; no temperature or duty cycle listed
LoZ voltage / built-in non-contact detectionNeither listedNeither listedBoth; also AutoVolt
PowerTwo AA or optional GBA37V10Two AAA9 V alkaline
Standard accessoriesMS90 leads, pouch, AA batteriesCapped leads, thermocouple, AAA batteriesSilicone leads and holster

Sources: Bosch US manual, Klein product page and MM420 manual, and Fluke 117 specifications and manual. “Not listed” means the model's own documented functions; sibling models and comparison-chart columns are excluded.

  • Yes: Bosch covers voltage, continuity, resistance, capacitance and AC frequency
  • No: No dedicated µA/mA ranges, temperature, diode test or duty cycle listed for Bosch
  • Partly: Bosch suits the job only when its ranges and CAT rating meet that job

Alternative for microamps and temperature: Klein MM420

Choose the MM420 if the Bosch function list misses your actual work. Klein documents a 400 µA DC range with 0.1 µA resolution, plus temperature, diode testing and duty cycle. It includes test leads with category shields, a thermocouple and batteries. The supplied thermocouple is suitable only below 180°C, separately from the meter's wider temperature range.

Klein Tools MM420 Auto-Ranging True RMS Digital Multimeter (600V)

Klein Tools

Klein Tools MM420

A 4,000-count auto-ranging True RMS multimeter rated CAT III 600V that measures up to 600 V and 10 A, plus temperature, capacitance, frequency and duty cycle.

Check package and model options

  • 600 V max
  • 10 A max
  • 4,000 counts
  • CAT III 600V

For that requirement, dedicated functions are a stronger reason to choose Klein than the Bosch rechargeable option. Our Fluke vs Klein multimeter guide compares the alternative packages in more detail.

Check price on Amazon

Alternative for ghost voltages: Fluke 117

Choose the 117 for its low-impedance voltage mode, which Fluke says reduces ghost-voltage readings, plus AutoVolt automatic AC/DC selection and VoltAlert non-contact detection. Its standard package includes silicone test leads and a holster.

Fluke 117 Electrician's True RMS Multimeter with Non-Contact Voltage

Fluke

Fluke 117

A compact 6,000-count True RMS multimeter for electricians, rated CAT III 600V, with built-in VoltAlert non-contact voltage detection, automatic AC/DC selection and a low-impedance mode.

Check package and model options

  • 600 V max
  • 10 A max
  • 6,000 counts
  • CAT III 600V

It does not solve the small-current limitation: the specified 6.000 A range also resolves 1 mA, and its own function list has no temperature measurement. Buy it for its electrical-troubleshooting aids when those are the deciding features.

Check price on Amazon

Buying guide: leads, fuse, pouch and checkout

Keep the lead shields. Bosch rates the supplied leads CAT III 1000 V / CAT IV 600 V, 10 A with shields, and CAT II 1000 V, 10 A without them. The meter remains CAT III 600 V. Higher-rated leads do not upgrade the instrument; follow the manual's shield requirements and use only the specified accessories.

Match the whole fuse specification. The US manual calls for a fast-acting 10 A, 600 V fuse, 10 kA switching capacity, measuring 6.3 × 32 mm. A matching current number alone is insufficient. Follow Bosch's replacement instructions rather than substituting a generic fuse.

The included storage is a pouch. Bosch does not list a hard case or spare fuse in the standard US contents. Check those separately if they matter for a gift or a work kit; the magnetic hanger is also optional.

Check the package before ordering
  1. Match the identity

    Confirm the US meter identifier and its matching manual.

  2. Match the job

    Check small-current detail, missing functions and the required CAT rating.

  3. Match the contents

    Confirm leads, shields, pouch and power; add the rechargeable pack or hanger only when wanted.

Repeat that package check during a holiday sale: a bundle title is not a contents list. For measurement basics, read how to use a multimeter.

How we choose

We researched official Bosch US and UK pages, the linked US meter and battery manuals, and the Klein and Fluke documentation. Recommendations follow documented ranges, operating limits and package contents; thisMETER publishes no original readings here. Unresolved regional accessory identifiers remain explicit, and Bosch purchase links go to the maker while Amazon identifiers await owner confirmation.

Verdict

Start with the US GDM600-15 AA package when its documented functions cover your work. Add GBA37V10 for rechargeable power, allowing for removal during charging. Choose MM420 for microamps and temperature, or Fluke 117 for LoZ and non-contact detection; buy those functions before adding accessories to the Bosch.

Our picks at a glance

  1. Klein Tools MM420 Auto-Ranging True RMS Digital Multimeter (600V)
    1

    Klein Tools MM420

    Choose for: Small-current work, temperature or diode testing

    Check before buying: Rated CAT III 600V: not for service-entrance (CAT IV) work

  2. Fluke 117 Electrician's True RMS Multimeter with Non-Contact Voltage
    2

    Fluke 117

    Choose for: Electrical troubleshooting with True RMS and a low-impedance mode for ghost voltage.

    Limit: CAT III 600 V, not CAT IV; no mA/µA current ranges (the 6 A range resolves 1 mA).

Frequently asked questions

Which Bosch multimeter package should I buy in the US?

Start with the GDM600-15 on Bosch's US page, order 0601077310. The documented package includes the meter, a tool pouch, MS90 test leads and two AA batteries. The GBA37V10 rechargeable battery and magnetic hanger are separate purchases. Check the actual package contents before ordering, especially when a listing uses the spaced regional name GDM 600-15.

Does the Bosch GDM600-15 need a rechargeable battery?

No. Bosch's US package includes two AA batteries, and its manual specifies alkaline LR6 cells as one power option. The separately sold GBA37V10 is a 3.7 V, 1.0 Ah lithium-ion alternative. Choose it for a rechargeable routine, rather than treating it as a required accessory. The meter manual requires removing the pack for charging.

Can I charge the GDM600-15 through USB-C while using it?

The meter manual requires removing the lithium-ion pack from the tool to charge it through the pack's USB-C port. It specifies a 5 V DC, 500 mA supply and recommended cables. Bosch's battery page describes charging while installed in a laser measure; that statement does not establish permission to charge this multimeter while using it.

Does the Bosch GDM600-15 measure microamps, temperature or diodes?

The US manual lists voltage, current, resistance, capacitance, AC frequency and continuity. Its smallest current range is 6.000 A with 0.001 A resolution; it lists no dedicated microamp or milliamp range, temperature, diode test or duty cycle. Choose the Klein MM420 when those functions are required, checking the supplied thermocouple's separate temperature limit.

Is the Bosch GDM600-15 waterproof or rated CAT IV?

Bosch specifies IP65 and CAT III 600 V for the meter, and the manual restricts it to indoor use. The supplied leads have higher category ratings with their shields fitted, but those ratings do not increase the meter's rating. The manual also prohibits use when the tool surface or your hands are wet. Follow the complete instrument and accessory instructions.

Related guides