Skip to content

Klein Tools

Klein Tools CL710 600A AC/DC Auto-Ranging True RMS Clamp Meter

A 6,000-count True RMS clamp meter that measures AC and DC current to 600 A and voltage to 1000 V, with a low-impedance mode and non-contact voltage detection in the jaw.

Klein Tools CL710 600A AC/DC True RMS clamp meter, three-quarter front view
1 / 5 · hero · hover to zoom

Photo: Klein Tools

Key facts

AC and DC current
60 A and 600 A ranges; ±(2.0% + 8) on 60 A, ±(2.0% + 5) on 600 A; AC 50 to 60 Hz
DC voltage
600 mV to 1000 V; ±(0.5% + 8) on 600 mV, ±(0.8% + 3) on 6 to 600 V, ±(1.0% + 3) on 1000 V
AC voltage (True RMS)
600 mV to 1000 V, 45 to 400 Hz; ±(1.8% + 8) on 600 mV, ±(0.9% + 5) on 6 to 600 V, ±(1.2% + 5) on 1000 V
Low impedance (LoZ)
±(2.5% + 8) AC V, ±(2.0% + 5) DC V
Resistance
600 Ω to 60 MΩ; ±(1.2% + 5) up to 6 MΩ
Capacitance
60 nF to 6,000 µF ranges (0.01 nF resolution on the 60 nF range)
Frequency
10 Hz to 60 kHz

Which version should you buy?

This page covers: Klein Tools CL710 clamp meter.

  • CL710 clamp meter

    This page

    Model: CL710

    What differs
    AC/DC clamp meter with LoZ, voltage detection and a lit dial. Its specifications and manual provide no temperature, DC microamp or worklight function.
    Best for
    General electrical work needing AC/DC clamp measurements and LoZ.
  • CL810 with worklight

    Model: CL810

    What differs
    Adds a worklight, DC microamp readings, temperature via thermocouple and inrush measurement.
    Best for
    HVAC and motor troubleshooting needing those extra measurements or light at the work area.

Watch out

  • Both are AC/DC clamp meters; check CL710 versus CL810 rather than relying on the current rating.
  • The CL710’s illuminated dial is not the CL810’s worklight.
  • Do not infer a CL710 temperature function from a thermocouple mentioned in a listing or feature bullet.

Why people pick it

  • Measures DC current as well as AC, which car, solar and battery work needs
  • CAT IV 600V and CAT III 1000V rating
  • LoZ mode to rule out ghost voltage, plus non-contact detection in the jaw
  • 6,000-count display that stays readable in sunlight, per Klein

Know before you buy

  • No DC microamp range, so it can't read HVAC flame-sensor current
  • The lowest current range is 60 A (10 mA steps), so very small loads read coarsely
  • No temperature function in the manual
  • Jaw opens to 1.4 in, smaller than the CL390's 1.6 in

Full specifications

AC and DC current60 A and 600 A ranges; ±(2.0% + 8) on 60 A, ±(2.0% + 5) on 600 A; AC 50 to 60 Hz
DC voltage600 mV to 1000 V; ±(0.5% + 8) on 600 mV, ±(0.8% + 3) on 6 to 600 V, ±(1.0% + 3) on 1000 V
AC voltage (True RMS)600 mV to 1000 V, 45 to 400 Hz; ±(1.8% + 8) on 600 mV, ±(0.9% + 5) on 6 to 600 V, ±(1.2% + 5) on 1000 V
Low impedance (LoZ)±(2.5% + 8) AC V, ±(2.0% + 5) DC V
Resistance600 Ω to 60 MΩ; ±(1.2% + 5) up to 6 MΩ
Capacitance60 nF to 6,000 µF ranges (0.01 nF resolution on the 60 nF range)
Frequency10 Hz to 60 kHz
DC microampsNot offered
Non-contact voltageBuilt into the clamp jaw, with sound and light that intensify near a live conductor
Display6,000-count transflective reverse-contrast LCD; illuminated dial
Jaw opening1.4 in (3.6 cm)
Other functionsContinuity, diode test, Min/Max, Rel/Zero, data hold
Safety ratingCAT IV 600V, CAT III 1000V, Class 2, double insulation
Safety standardsIEC/EN 61010-1 and 61010-2-032; conforms to UL 61010-1 and 61010-2-032; certified to CSA C22.2 No. 61010-1 and 61010-2-032
CalibrationAccurate for one year (per the manual)
Ingress protectionIP40
Drop protection2 m (6.6 ft)
Power3 × AAA
MountingBack mount for Klein's optional magnetic hanger (69445 or 69417); side test-lead holder
In the boxClamp meter, right-angle test leads, storage pouch, instructions, 3 × AAA batteries

From manufacturer documentation, checked November 2, 2026. Spotted an error? Tell us.