Manufacturer specifications recorded by thisMETER. These are not our own measurements. References belong to this product record; a field-by-field source mapping is not claimed.
- Insulation test voltages
- 50 V, 100 V, 250 V, 500 V and 1000 V fixed ranges, plus a user-variable range from 10 V to 1000 V in 1 V steps
- Insulation resistance range
- 2 GΩ to 200 GΩ depending on test voltage (10 GΩ at 50 V up to 200 GΩ at 1000 V)
- Test voltage accuracy
- Stabilised, feedback-controlled output held within -0% +2%, versus the 10 to 20% overvoltage typical of industry-standard testers
- Continuity range
- Single auto-ranging 0.01 Ω to 1 MΩ, with 200 mA or 20 mA test currents and lead null up to 9.00 Ω
- Voltage measurement
- True RMS AC and DC, 0.0 mV to 600 V, with frequency display 15 Hz to 400 Hz
- PI and DAR
- Polarization Index (10 min / 1 min) and Dielectric Absorption Ratio (60 s / 15 s and 60 s / 30 s) functions, with timed testing
- Capacitance measurement
- 1 nF to 10 μF, ±5% ±2 digits (0.1 nF to 1 nF unspecified)
- Result storage
- Over 1000 test results stored on the instrument, transferable to a CSV file (Bluetooth download is on the MIT430/2)
- Live circuit protection
- Insulation testing is inhibited on live circuits above a user-set 25/30/50/75/100 V (default 50 V); protection works even if the fuse has failed
- Safety standards
- Meets IEC 61010 and EN 61557; EN 61010-1 to 600 V phase to earth, Category IV; IP54
- Power
- 6 x AA alkaline or NiMH rechargeable cells; minimum 3000 insulation tests at 1000 V (5 s on / 55 s off duty cycle)
- Dimensions and weight
- 228 x 108 x 63 mm (9.00 x 4.25 x 2.32 in); 600 g (1.32 lb), 1.75 kg with carry case
- Included accessories
- Red/black silicone test leads with probes and clips, SP5 remote switch probe, 6 x AA alkaline batteries, carry case, calibration certificate (order code 1004-739)
- Fuse
- 1 x 500 mA (FF) 1000 V 32 x 6 mm ceramic high-breaking-capacity fuse (min. 30 kA); glass fuses must not be fitted
Record checked 2026-11-05.